AEGIS Touchstone Testing Implementation Guide

This is the Version 1.1.0 Release of the Touchstone Testing Implementation Guide, based on FHIR Version 4.0.1. See the Directory of published versions

XML Format: TestScript-ehr-smart-launch

Raw xml



<TestScript xmlns="http://hl7.org/fhir">
  <id value="ehr-smart-launch"/>
  <meta>
    <profile
             value="http://touchstone.aegis.net/touchstone/fhir/testing/StructureDefinition/testscript"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative</b></p><h3>Ids</h3><table class="grid"><tr><td>-</td></tr><tr><td>*</td></tr></table><h3>Meta</h3><table class="grid"><tr><td>-</td></tr><tr><td>*</td></tr></table><p><b>url</b>: <a href="http://touchstone.aegis.net/touchstone/fhir/testing/TestScript/ehr-smart-launch">http://touchstone.aegis.net/touchstone/fhir/testing/TestScript/ehr-smart-launch</a></p><p><b>version</b>: 1.1.0</p><p><b>name</b>: EHRSMARTLaunch</p><p><b>status</b>: active</p><p><b>date</b>: 2020-08-27</p><p><b>publisher</b>: AEGIS.net, Inc.</p><p><b>contact</b>: Touchstone Support: <a href="mailto:Touchstone_Support@aegis.net">Touchstone_Support@aegis.net</a></p><p><b>description</b>: Demonstrate the use of the smart-launch operation and the new extension operation-smartLaunchRequestId.</p><p><b>jurisdiction</b>: <span title="Codes: {urn:iso:std:iso:3166 US}">United States of America</span></p><p><b>copyright</b>: (c) AEGIS.net, Inc. 2015+</p><blockquote><p><b>test</b></p><h3>Ids</h3><table class="grid"><tr><td>-</td></tr><tr><td>*</td></tr></table><p><b>name</b>: EHR Launch With Practitioner Scope</p><p><b>description</b>: Perform EHR SMART launch sequence and test browser redirect.</p><blockquote><p><b>action</b></p><h3>Operations</h3><table class="grid"><tr><td>-</td><td><b>Extension</b></td><td><b>Type</b></td><td><b>Description</b></td><td><b>EncodeRequestUrl</b></td></tr><tr><td>*</td><td></td><td><span title="{http://touchstone.aegis.net/touchstone/fhir/testing/CodeSystem/codesystem-testscript-operation-codes smart-launch}">SMART on FHIR Launch</span></td><td>EHR server redirects client browser to Touchstone app launch URL</td><td>false</td></tr></table></blockquote><blockquote><p><b>action</b></p><h3>Asserts</h3><table class="grid"><tr><td>-</td><td><b>Description</b></td><td><b>Direction</b></td><td><b>Operator</b></td><td><b>RequestURL</b></td><td><b>SourceId</b></td><td><b>WarningOnly</b></td></tr><tr><td>*</td><td>EHR server redirects client browser to Touchstone app launch URI. Client browser sent from EHR server to app launch URI of client app as described in SMART EHR Launch Sequence.</td><td>request</td><td>contains</td><td>/oauth2/smart/launch</td><td>smartLaunchRequest1</td><td>false</td></tr></table></blockquote></blockquote></div>
  </text>
  <url
       value="http://touchstone.aegis.net/touchstone/fhir/testing/TestScript/ehr-smart-launch"/>
  <version value="1.1.0"/>
  <name value="EHRSMARTLaunch"/>
  <status value="active"/>
  <date value="2020-08-27"/>
  <publisher value="AEGIS.net, Inc."/>
  <contact>
    <name value="Touchstone Support"/>
    <telecom>
      <system value="email"/>
      <value value="Touchstone_Support@aegis.net"/>
      <use value="work"/>
    </telecom>
  </contact>
  <description
               value="Demonstrate the use of the smart-launch operation and the new extension operation-smartLaunchRequestId."/>
  <jurisdiction>
    <coding>
      <system value="urn:iso:std:iso:3166"/>
      <code value="US"/>
      <display value="United States of America"/>
    </coding>
  </jurisdiction>
  <copyright value="(c) AEGIS.net, Inc. 2015+"/>
  <test id="EHRLaunchWithPractitionerScope">
    <name value="EHR Launch With Practitioner Scope"/>
    <description
                 value="Perform EHR SMART launch sequence and test browser redirect."/>
    <action>
      <operation>
        <extension
                   url="http://touchstone.aegis.net/touchstone/fhir/testing/StructureDefinition/testscript-operation-smartLaunchRequestId">
          <valueId value="smartLaunchRequest1"/>
        </extension>
        <type>
          <system
                  value="http://touchstone.aegis.net/touchstone/fhir/testing/CodeSystem/codesystem-testscript-operation-codes"/>
          <code value="smart-launch"/>
        </type>
        <description
                     value="EHR server redirects client browser to Touchstone app launch URL"/>
        <encodeRequestUrl value="false"/>
      </operation>
    </action>
    <action>
      <assert>
        <description
                     value="EHR server redirects client browser to Touchstone app launch URI. Client browser sent from EHR server to app launch URI of client app as described in SMART EHR Launch Sequence."/>
        <direction value="request"/>
        <operator value="contains"/>
        <requestURL value="/oauth2/smart/launch"/>
        <sourceId value="smartLaunchRequest1"/>
        <warningOnly value="false"/>
      </assert>
    </action>
  </test>
</TestScript>